SCOPE

OEM / Machine type MHI Steam Turbine
Output 37.5MW
Project Type Static Load and Eigen Frequency analyses 
Product  Rotor Blade Stage 5 LH+RH
Material(s) AISI403SS

PURPOSE

Technical verification of a rotor blade re-design against original design.

REASONS FOR IMPLEMENTING A RE-DESIGN

  1. Increase power and efficiency
  2. Easier assembly and dis-assembly of single blades

INTRODUCTION

Static load and Eigen Frequency analyses have been carried out for a steam turbine blade with a fir tree root. Thereby, a part of the rotor disc has been included into the model in order to establish realistic root fixation constraints. 

The static load calculations have been performed for both 100 % and 110 % rotational speed. The result of these calculations deliver information on the stress loading at the blade root and on the contact status of the blade snubbers.